ISO 15693-Compliant 1Kb Memory Fob
Request Data for the Read Multiple Blocks Command
REQUEST FLAGS
(1 Byte)
COMMAND
23h
UID
(8 Bytes)
STARTING BLOCK
NUMBER
(1 Byte)
NUMBER OF BLOCKS
(1 Byte)
Response Data for the Read Multiple Blocks Command (No Error, Option_flag Not Set)
RESPONSE FLAGS
00h
MEMORY DATA
(8 to 24 Bytes)
Response Data for the Read Multiple Blocks Command (No Error, Option_flag Set)
RESPONSE FLAGS
00h
SECURITY STATUS
(1 Byte)
MEMORY DATA
(8 Bytes)
Repeated as needed
Request Data for the Custom Read Block
REQUEST FLAGS
(1 Byte)
COMMAND
A4h
MFG CODE
2Bh
UID
(8 Bytes)
BLOCK NUMBER
(1 Byte)
Response Data for the Custom Read Block (No Error, Option_flag Not Set)
RESPONSE FLAGS
00h
MEMORY DATA
(8 Bytes)
INTEGRITY BYTES
(2 Bytes)
Response Data for the Custom Read Block (No Error, Option_flag Set)
RESPONSE FLAGS
00h
SECURITY STATUS
(1 Byte)
MEMORY DATA
(8 Bytes)
INTEGRITY BYTES
(2 Bytes)
Read Multiple Blocks
The Read Multiple Blocks command allows for retriev-
ing the data of up to three memory blocks. This com-
mand uses two command-specific parameters, which
are the starting block number and the number of blocks
to read. Valid starting block numbers are 00h to 11h.
Permissible number of block values are 0, 1, and 2,
corresponding to 1, 2, and 3 blocks. A request that
attempts reading beyond block number 11h generates
a response with error code 10h. If the Option_flag bit is
set, the response includes the block’s security status.
The security status codes are the same when reading
single blocks. See the Read Single Block section for
more details.
Custom Read Block
The Custom Read Block command allows for retrieving
the data of a single memory block. This command uses
one command-specific parameter, which is the memory
block number. Valid block numbers are 00h to 11h. If
the Option_flag bit is set, the response includes the
block’s security status. The security status codes are
the same as when reading single blocks. See the Read
Single Block section for more details.
18
______________________________________________________________________________________
相关PDF资料
MAX6612MXK+T IC TEMP SENSOR ANLG SC70-5
MAX6613MXK+TCA3 IC ANLG TEMP SENSOR SC70-5
MAX66140K-000AA+ IC RFID UID 64BIT TYPE B KEY FOB
MAX6667AUT+T IC TEMP SENSOR PWM OUT SOT23-6
MAX6672AXK+T IC TEMP SENSOR PWM OUT SC70-5
MAX6676AUT+T IC TEMP SENSOR PWM OUT SOT23-6
MAX6686UA75L+ IC SW TEMP DUAL OUT 8-UMAX
MAX6688AU40H+ IC SW TEMP REMOTE 8-UMAX
相关代理商/技术参数
MAX66120K-00AA+ 制造商:Maxim Integrated Products 功能描述:ISO 15693-COMPLIANT 1KB MEMORY FOB - Rail/Tube
MAX6612MXK 制造商:Maxim Integrated Products 功能描述:HIGH-SLOPE, LOW-POWER, ANALOG TEMPERATURE SEN - Cut Tape Product
MAX6612MXK+ 制造商:Maxim Integrated Products 功能描述:TEMP SENSOR ANLG 5PIN SC-70 - Rail/Tube 制造商:Maxim Integrated Products 功能描述:TEMP SENSOR H SLOPE L POWER SC70 制造商:Maxim Integrated Products 功能描述:TEMP SENSOR, H SLOPE, L POWER, SC70
MAX6612MXK+T 功能描述:板上安装温度传感器 Low-Power Analog Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6612MXK-T 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6613MXK 制造商:Maxim Integrated Products 功能描述:LOW-VOLTAGE ANALOG TEMPERATURE SENS - Rail/Tube
MAX6613MXK/V+ 制造商:Maxim Integrated Products 功能描述:- Rail/Tube
MAX6613MXK/V+T 功能描述:板上安装温度传感器 Low-Power Analog Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor